Causes And Treatment Of Common Trouble Of Pen Making Equipment

May 19, 2017 Leave a message

1, assembly machine can not run properly

If the assembler does not function properly, the following checks should be made:

(1) Check whether the main power supply is normal

(2) check the fuse is normal

(3) check the other should have a power supply where the normal view of the reasons and repair

2 Feeding speed suddenly decreases

Assembly machine discharge rate suddenly can be reduced in the following reasons.

(1) The vibration system is blocked

May be due to the hopper and the hood between the too close, there is no air gap, so that the vibration of the vibration system blocked. Check the above clearance and relax with the hopper to the right position.

(2) plate spring break

Open the cover, check the spring, replace the broken spring.

(3) internal spiral groove contamination

Use gasoline or alcohol to clean the contaminants in the spiral groove inside the hopper.